Test for I-deas Utilities

Moving RMS
Calculate the moving RMS for time histories based on a user-specified averaging time.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
MovingRMSZIP857 Bytes International
White Background
Sets background to white with appropriate graph colour defaults.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
WhiteBackgroundZIP1.6 Kb International
Example Toolbars
Example of toolbars for acquisition, modal, time/function operations.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
ExampleToolbarsZIP578.8 Kb International
Balancing
Single plane and two plane balancing, includes user guide.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
BalanceZIP119.2 Kb United Kingdom
Closed Loop for Standard Measurements
Automated closed loop control setup, includes user guide.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
closedLoopStandardZIP601 Bytes United Kingdom
Delta Rosette
Calculates principal strains from a delta rosette.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
DeltaRosetteZIP1.1 Kb International
Frequency to Orders
Converts the X-axis from frequency to orders on spectral maps.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
Frq2OrdZIP1.6 Kb International
Rectangular Rosette
Calculates principal strains from a rectangular rosette.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
RectRosetteZIP1.2 Kb International
Spectrum Analyzer
Uses 1 form to setup all acquisition parameters, includes user guide.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
SpectrumAnalyzerZIP9.6 Kb United Kingdom
Virtual Tachs
Sets up the virtual tachs for VXI, includes user guide.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
VirtualTachZIP5.7 Kb United Kingdom
Hold RPM Range
User selects set and RPM range, then maximum of all spetra in range is computed.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
HoldRPMRangeZIP678 Bytes International
Two Functions
Converts 2 functions vs. time into 1st function vs the 2nd function.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
TwoFcnZIP88.1 Kb International
Integrate Time History
Integrates a time history using filtering.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
IntegrateZIP1.7 Kb International
Differentiate
Differentiates a time history using filtering.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
DifferentiateZIP1.3 Kb International
Random Excitation
Sets-up the data acquisition parameters for random excitation.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
RandomZIP507 Bytes International
Burst Random Excitation
Sets-up the data acquisition parameters for burst random excitation.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
BurstZIP643 Bytes International
Impact Excitation
Sets-up the data acquisition parameters for impact excitation.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
ImpactZIP565 Bytes International
Closed Loop for I-deas Test
Sets-up the data acquisition parameters for swept sine excitation using Closed Loop.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
ClosedLoopIdeasZIP601 Bytes International
Envelope Time History
Calculates the envelope of a time history using the Hilbert Transform.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
EnvelopeZIP2.5 Kb InternationalSeptember 4. 2002
Decaying Sinusoid
Calculates the log decrement of a decaying sinusoid using the envelope.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
DecayZIP1.8 Kb International
Controller Gain
Microsoft® Visual Basic® programme to generate dapcl_fc.ini file to change the closed loop controller gain.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
ControllerGainZIP5.5 Kb International
Accelerometer Calibration
Microsoft® Visual Basic® programme used for accelerometer calibration with I-deas Swept Sine and Closed Loop control.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
CalibrateZIP8.9 Kb International
Function Legend
Sets up legends on up to 19 functions (for black and white background).
FilnavnFiltypeStørrelseSprogFrigivelsesdato
LegendZIP3.6 Kb International
Switch
Switch reference and response coordinates in function ADF.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
SwitchZIP1.3 Kb InternationalAugust 29. 2002
RPC to Post Transient
Import all the RPCIII files from the current directory and do a transient post-processing on all the files with the same setting as the first one.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
RPCtoPostTransientZIP1.9 Kb International
Batch ADF Import
Allows the user to import/attach multiple ADFs at one time.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
BatchADFImportZIP1.5 Kb International
Automate Select Post-Process
Automates post-processing of select time records, re-ordering references if required.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
SelectRefZIP1.5 Kb International
Change Color for CGM
Change colour scheme for CGM creation for 2D and 3D graphs.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
ColorForCGMZIP674 Bytes International
Scatter Diagram
Create phase scatter diagram.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
ScatterZIP2.4 Kb International
Multi Source RMS
Set the RMS level of the source, based upon a user-defined feedback channel.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
MultiSourceRMSZIP3.1 Kb International
DAC Shaped RMS
Spectrum shaping using DAC output.
FilnavnFiltypeStørrelseSprogFrigivelsesdato
DacShapedRMSZIP4.8 Kb International
  
Vi hjælper vores kunder med at måle og håndtere kvaliteten af lyd og vibration i deres produkter og i miljøet

Copyright © Brüel & Kjær. All Rights Reserved Virksomhedsinformation Privacy Policy Juridisk information